[FIDOCAD] FJC C 3.0 FJC A 0.8 FJC B 0.8 MC 148 22 2 1 lt_lib.cap FCJ TY 150 17 2 2 0 0 0 Calibri C14 TY 150 22 2 2 0 0 0 Calibri .01u MC 188 106 3 0 ey_libraries.refpnt0 MC 199 40 2 1 lt_lib.pnp FCJ TY 197 30 2 2 0 0 0 Calibri Q7 TY 200 40 2 2 0 0 0 Calibri 2N344 MC 100 108 1 0 ey_libraries.refpnt0 MC 176 22 1 0 lt_lib.diode FCJ TY 178 17 2 2 0 0 0 Calibri D1 TY 178 23 2 2 0 0 0 Calibri 1N2326 MC 216 80 2 0 ey_libraries.refpnt0 MC 166 22 2 1 lt_lib.cap FCJ TY 168 16 2 2 0 0 0 Calibri C16 TY 168 23 2 2 0 0 0 Calibri .01u MC 258 62 0 0 115 FCJ TY 260 62 2 2 0 0 0 Calibri R20 TY 260 66 2 2 0 0 0 Calibri 3.6K MC 166 34 2 1 lt_lib.cap FCJ TY 168 28 2 2 0 0 0 Calibri C17 TY 168 35 2 2 0 0 0 Calibri .01u MC 246 60 3 0 115 FCJ TY 246 55 2 2 0 0 0 Calibri R21 TY 248 62 2 2 0 0 0 Calibri 390 MC 182 40 0 0 120 FCJ TY 188 35 2 2 0 0 0 Calibri L1 TY 184 40 2 2 0 0 0 Calibri 51u MC 222 32 2 1 lt_lib.cap FCJ TY 224 26 2 2 0 0 0 Calibri C18 TY 224 33 2 2 0 0 0 Calibri .001u MC 206 54 0 0 120 FCJ TY 207 49 2 2 0 0 0 Calibri L2 TY 208 54 2 2 0 0 0 Calibri 51u MC 212 26 2 1 lt_lib.cap FCJ TY 214 20 2 2 0 0 0 Calibri C19 TY 214 27 2 2 0 0 0 Calibri .47u MC 182 48 1 0 lt_lib.cap FCJ TY 177 43 2 2 0 0 0 Calibri C15 TY 179 50 2 2 0 0 0 Calibri 20p MC 72 158 1 0 ey_libraries.refpnt0 MC 176 56 0 0 115 FCJ TY 178 56 2 2 0 0 0 Calibri R17 TY 178 60 2 2 0 0 0 Calibri 10K MC 237 92 2 1 lt_lib.pnp FCJ TY 238 88 2 2 0 0 0 Calibri Q1 TY 238 92 2 2 0 0 0 Calibri 2N274 MC 176 34 1 0 lt_lib.diode FCJ TY 178 29 2 2 0 0 0 Calibri D2 TY 178 33 2 2 0 0 0 Calibri 1N2326 MC 254 80 1 0 115 FCJ TY 244 75 2 2 0 0 0 Calibri R23 TY 246 82 2 2 0 0 0 Calibri 10K MC 231 54 2 1 lt_lib.pnp FCJ TY 228 44 2 2 0 0 0 Calibri Q6 TY 234 50 2 2 0 0 0 Calibri 2N597 MC 248 92 1 1 lt_lib.cap FCJ TY 243 87 2 2 0 0 0 Calibri C20 TY 244 94 2 2 0 0 0 Calibri .01u MC 234 28 0 0 115 FCJ TY 236 28 2 2 0 0 0 Calibri R19 TY 236 32 2 2 0 0 0 Calibri 10K MC 228 96 0 0 115 FCJ TY 230 96 2 2 0 0 0 Calibri R24 TY 230 100 2 2 0 0 0 Calibri 1K MC 244 28 1 0 120 FCJ TY 246 28 2 2 0 0 0 Calibri L3 TY 246 32 2 2 0 0 0 Calibri 12.5m MC 276 88 0 0 ey_libraries.refpnt0 MC 240 60 0 0 lt_lib.diode FCJ TY 236 62 2 2 0 0 0 Calibri 1N484 TY 236 55 2 2 0 0 0 Calibri D3 MC 16 30 1 0 ey_libraries.refpnt0 MC 52 52 0 0 ey_libraries.refpnt0 MC 54 60 1 0 ey_libraries.refpnt0 MC 50 30 1 0 ey_libraries.refpnt0 MC 80 24 2 0 ey_libraries.refpnt0 MC 114 60 3 0 ey_libraries.refpnt0 MC 114 30 3 0 ey_libraries.refpnt0 MC 124 24 2 0 ey_libraries.refpnt0 MC 154 60 3 0 ey_libraries.refpnt0 MC 212 32 0 0 115 FCJ TY 214 32 2 2 0 0 0 Calibri R22 TY 214 36 2 2 0 0 0 Calibri 90 MC 124 52 0 0 ey_libraries.refpnt0 MC 176 66 0 0 ey_libraries.refpnt0 MC 228 106 0 0 ey_libraries.refpnt0 MC 258 130 0 0 ey_libraries.refpnt0 MC 216 106 0 0 ey_libraries.refpnt0 MC 198 82 2 0 ey_libraries.refpnt0 MC 186 118 3 0 120 FCJ TY 188 109 2 2 0 0 0 Calibri L5 TY 188 113 2 2 0 0 0 Calibri 1u MC 168 152 0 0 ey_libraries.refpnt0 MC 276 28 0 0 ey_libraries.refpnt0 MC 216 100 2 1 lt_lib.cap FCJ TY 218 94 2 2 0 0 0 Calibri C21 TY 218 101 2 2 0 0 0 Calibri 150p MC 42 60 3 0 ey_libraries.refpnt0 MC 242 120 3 0 115 FCJ TY 242 115 2 2 0 0 0 Calibri R25 TY 244 122 2 2 0 0 0 Calibri 3.3K MC 38 60 3 1 lt_lib.cap FCJ TY 34 55 2 2 0 0 0 Calibri C2 TY 34 62 2 2 0 0 0 Calibri .01u MC 258 108 2 1 115 FCJ TY 260 98 2 2 0 0 0 Calibri R26 TY 260 103 2 2 0 0 0 Calibri 1K MC 20 30 3 0 lt_lib.cap FCJ TY 16 25 2 2 0 0 0 Calibri C3 TY 16 32 2 2 0 0 0 Calibri .01u MC 258 126 2 1 lt_lib.cap FCJ TY 260 120 2 2 0 0 0 Calibri C22 TY 260 127 2 2 0 0 0 Calibri .01u MC 64 18 0 0 115 FCJ TY 66 18 2 2 0 0 0 Calibri R5 TY 66 22 2 2 0 0 0 Calibri 15K MC 210 120 3 1 lt_lib.cap FCJ TY 205 115 2 2 0 0 0 Calibri C23 TY 206 122 2 2 0 0 0 Calibri 200p MC 64 48 0 0 115 FCJ TY 66 48 2 2 0 0 0 Calibri R6 TY 66 52 2 2 0 0 0 Calibri 4.7K MC 210 92 3 1 lt_lib.cap FCJ TY 205 87 2 2 0 0 0 Calibri C24 TY 207 94 2 2 0 0 0 Calibri 25p MC 148 40 0 0 ey_libraries.refpnt0 MC 198 106 2 1 lt_lib.cap FCJ TY 200 100 2 2 0 0 0 Calibri C25 TY 200 107 2 2 0 0 0 Calibri 100p MC 64 62 0 0 115 FCJ TY 66 62 2 2 0 0 0 Calibri R8 TY 66 66 2 2 0 0 0 Calibri 2.2K MC 198 86 2 1 lt_lib.cap FCJ TY 200 80 2 2 0 0 0 Calibri C26 TY 200 87 2 2 0 0 0 Calibri 100p MC 58 60 3 0 lt_lib.cap FCJ TY 54 55 2 2 0 0 0 Calibri C4 TY 54 62 2 2 0 0 0 Calibri .01u MC 186 104 3 0 120 FCJ TY 188 94 2 2 0 0 0 Calibri L4 TY 188 99 2 2 0 0 0 Calibri 1u MC 54 30 3 0 lt_lib.cap FCJ TY 50 25 2 2 0 0 0 Calibri C5 TY 50 32 2 2 0 0 0 Calibri .01u MC 28 62 0 0 115 FCJ TY 30 62 2 2 0 0 0 Calibri R4 TY 30 66 2 2 0 0 0 Calibri 2.2K MC 98 18 0 0 115 FCJ TY 100 18 2 2 0 0 0 Calibri R13 TY 100 22 2 2 0 0 0 Calibri 15K MC 271 18 0 0 lt_lib.gen_v FCJ TY 280 18 2 2 0 0 0 Calibri V1 TY 280 22 2 2 0 0 0 Calibri 15 MC 18 108 1 0 ey_libraries.refpnt0 MC 271 78 0 0 lt_lib.gen_v FCJ TY 280 78 2 2 0 0 0 Calibri V2 TY 280 82 2 2 0 0 0 Calibri -15 MC 222 68 0 0 ey_libraries.refpnt0 MC 74 46 3 1 lt_lib.cap FCJ TY 70 41 2 2 0 0 0 Calibri C7 TY 70 48 2 2 0 0 0 Calibri .01u MC 102 106 3 1 120 FCJ TY 94 96 2 2 0 0 0 Calibri L10 TY 96 101 2 2 0 0 0 Calibri 1u MC 110 46 3 1 lt_lib.cap FCJ TY 106 41 2 2 0 0 0 Calibri C8 TY 106 48 2 2 0 0 0 Calibri .01u MC 102 120 3 1 120 FCJ TY 94 111 2 2 0 0 0 Calibri L11 TY 96 115 2 2 0 0 0 Calibri 1u MC 156 46 3 1 lt_lib.cap FCJ TY 152 41 2 2 0 0 0 Calibri C9 TY 152 48 2 2 0 0 0 Calibri 7.5p MC 116 128 0 0 115 FCJ TY 118 128 2 2 0 0 0 Calibri R31 TY 118 132 2 2 0 0 0 Calibri 330 MC 61 38 2 1 lt_lib.pnp FCJ TY 62 34 2 2 0 0 0 Calibri Q3 TY 62 38 2 2 0 0 0 Calibri 2N344 MC 168 128 0 0 115 FCJ TY 170 130 2 2 0 0 0 Calibri R32 TY 170 132 2 2 0 0 0 Calibri 47 MC 52 42 0 0 115 FCJ TY 54 42 2 2 0 0 0 Calibri R7 TY 54 46 2 2 0 0 0 Calibri 1K MC 25 38 2 1 lt_lib.pnp FCJ TY 26 34 2 2 0 0 0 Calibri Q2 TY 26 38 2 2 0 0 0 Calibri 2N344 MC 135 38 2 1 lt_lib.pnp FCJ TY 136 34 2 2 0 0 0 Calibri Q5 TY 136 38 2 2 0 0 0 Calibri 2N344 MC 28 18 0 0 115 FCJ TY 30 18 2 2 0 0 0 Calibri R1 TY 30 22 2 2 0 0 0 Calibri 15K MC 124 42 0 0 115 FCJ TY 126 42 2 2 0 0 0 Calibri R18 TY 126 46 2 2 0 0 0 Calibri 2K MC 28 48 0 0 115 FCJ TY 30 48 2 2 0 0 0 Calibri R2 TY 30 51 2 2 0 0 0 Calibri 4.7K MC 122 112 3 1 lt_lib.varactor FCJ TY 124 106 2 2 0 0 0 Calibri D6 TY 124 114 2 2 0 0 0 Calibri V47 MC 150 60 3 1 lt_lib.cap FCJ TY 145 55 2 2 0 0 0 Calibri C12 TY 146 62 2 2 0 0 0 Calibri .01u MC 122 100 3 1 lt_lib.varactor FCJ TY 124 95 2 2 0 0 0 Calibri D7 TY 124 102 2 2 0 0 0 Calibri V47 MC 148 36 2 1 lt_lib.cap FCJ TY 150 31 2 2 0 0 0 Calibri C13 TY 150 37 2 2 0 0 0 Calibri .01u MC 98 48 0 0 115 FCJ TY 100 48 2 2 0 0 0 Calibri R14 TY 100 52 2 2 0 0 0 Calibri 4.7K MC 40 46 3 1 lt_lib.cap FCJ TY 36 41 2 2 0 0 0 Calibri C6 TY 36 48 2 2 0 0 0 Calibri .01u MC 80 36 2 1 115 FCJ TY 82 26 2 2 0 0 0 Calibri R15 TY 82 31 2 2 0 0 0 Calibri 1K MC 36 102 2 1 lt_lib.cap FCJ TY 38 96 2 2 0 0 0 Calibri C32 TY 38 103 2 2 0 0 0 Calibri 7.5p MC 98 62 0 0 115 FCJ TY 100 62 2 2 0 0 0 Calibri R16 TY 100 66 2 2 0 0 0 Calibri 2.2K MC 48 116 2 1 lt_lib.cap FCJ TY 50 111 2 2 0 0 0 Calibri C33 TY 50 117 2 2 0 0 0 Calibri 10p MC 110 60 3 1 lt_lib.cap FCJ TY 105 55 2 2 0 0 0 Calibri C10 TY 106 62 2 2 0 0 0 Calibri .01u MC 36 116 2 1 lt_lib.cap FCJ TY 38 110 2 2 0 0 0 Calibri C34 TY 38 117 2 2 0 0 0 Calibri 7.5p MC 110 30 1 0 lt_lib.cap FCJ TY 105 25 2 2 0 0 0 Calibri C11 TY 106 32 2 2 0 0 0 Calibri .01u MC 48 130 2 1 lt_lib.cap FCJ TY 50 124 2 2 0 0 0 Calibri C35 TY 50 131 2 2 0 0 0 Calibri 10p MC 138 18 0 0 115 FCJ TY 140 18 2 2 0 0 0 Calibri R9 TY 140 22 2 2 0 0 0 Calibri 15K MC 95 38 2 1 lt_lib.pnp FCJ TY 96 34 2 2 0 0 0 Calibri Q4 TY 96 38 2 2 0 0 0 Calibri 2N344 MC 138 48 0 0 115 FCJ TY 140 48 2 2 0 0 0 Calibri R10 TY 140 52 2 2 0 0 0 Calibri 4.7K MC 36 88 2 1 lt_lib.cap FCJ TY 38 83 2 2 0 0 0 Calibri C37 TY 38 89 2 2 0 0 0 Calibri 7.5p MC 124 36 2 1 115 FCJ TY 126 26 2 2 0 0 0 Calibri R11 TY 126 31 2 2 0 0 0 Calibri 1K MC 48 88 2 1 lt_lib.cap FCJ TY 50 83 2 2 0 0 0 Calibri C38 TY 50 89 2 2 0 0 0 Calibri 10p MC 138 62 0 0 115 FCJ TY 140 62 2 2 0 0 0 Calibri R12 TY 140 66 2 2 0 0 0 Calibri 2.2K MC 20 102 2 1 lt_lib.cap FCJ TY 22 96 2 2 0 0 0 Calibri C1 TY 22 103 2 2 0 0 0 Calibri {y*3p} MC 68 110 0 0 115 FCJ TY 68 116 2 2 0 0 0 Calibri {(1-x)*50K} TY 70 110 2 2 0 0 0 Calibri R34 MC 20 116 2 1 lt_lib.cap FCJ TY 22 110 2 2 0 0 0 Calibri C39 TY 22 117 2 2 0 0 0 Calibri {(1-y)*3p} MC 62 108 3 1 lt_lib.cap FCJ TY 57 103 2 2 0 0 0 Calibri C30 TY 58 110 2 2 0 0 0 Calibri 7.5p MC 108 106 3 0 120 FCJ TY 110 96 2 2 0 0 0 Calibri L8 TY 110 101 2 2 0 0 0 Calibri 1u MC 48 102 2 1 lt_lib.cap FCJ TY 50 96 2 2 0 0 0 Calibri C31 TY 50 103 2 2 0 0 0 Calibri 10p MC 108 120 3 0 120 FCJ TY 110 111 2 2 0 0 0 Calibri L9 TY 110 115 2 2 0 0 0 Calibri 1u MC 164 100 2 1 lt_lib.cap FCJ TY 166 94 2 2 0 0 0 Calibri C27 TY 166 101 2 2 0 0 0 Calibri 120p MC 88 108 2 1 lt_lib.cap FCJ TY 90 102 2 2 0 0 0 Calibri C29 TY 90 109 2 2 0 0 0 Calibri 120p MC 162 92 1 0 115 FCJ TY 152 87 2 2 0 0 0 Calibri R27 TY 154 94 2 2 0 0 0 Calibri 4.7K MC 222 62 0 0 lt_lib.gen_i FCJ TY 226 60 2 2 0 0 0 Calibri PWL( TY 226 64 2 2 0 0 0 Calibri 0 40u MC 162 120 1 0 115 FCJ TY 152 115 2 2 0 0 0 Calibri R28 TY 154 122 2 2 0 0 0 Calibri 4.7K MC 134 100 1 0 lt_lib.varactor FCJ TY 136 102 2 2 0 0 0 Calibri V47 TY 136 98 2 2 0 0 0 Calibri D4 MC 144 94 0 0 115 FCJ TY 146 94 2 2 0 0 0 Calibri R29 TY 146 98 2 2 0 0 0 Calibri 330 MC 92 153 1 0 lt_lib.gen_v FCJ TY 83 151 2 2 0 0 0 Calibri V3 TY 58 162 2 2 0 0 0 Calibri PULSE(-100m 100m 0 .1m .1m .5m 1.2m) MC 36 130 2 1 lt_lib.cap FCJ TY 38 124 2 2 0 0 0 Calibri C36 TY 38 131 2 2 0 0 0 Calibri 7.5p MC 144 140 3 1 lt_lib.cap FCJ TY 139 135 2 2 0 0 0 Calibri C28 TY 140 142 2 2 0 0 0 Calibri 100p MC 216 84 0 0 lt_lib.gen_i FCJ TY 220 75 2 2 0 0 0 Calibri I1 TY 220 78 2 2 0 0 0 Calibri SINE( MC 68 96 0 0 115 FCJ TY 70 102 2 2 0 0 0 Calibri {x*50K} TY 70 96 2 2 0 0 0 Calibri R33 MC 134 112 1 0 lt_lib.varactor FCJ TY 136 114 2 2 0 0 0 Calibri V47 TY 136 110 2 2 0 0 0 Calibri D5 MC 134 158 1 0 115 FCJ TY 125 153 2 2 0 0 0 Calibri R3 TY 126 160 2 2 0 0 0 Calibri 100K MC 84 62 2 1 lt_lib.cap FCJ TY 86 56 2 2 0 0 0 Calibri Cstray TY 86 63 2 2 0 0 0 Calibri .05p MC 180 108 1 0 120 FCJ TY 174 108 2 2 0 0 0 Calibri L6 TY 174 113 2 2 0 0 0 Calibri 1u MC 194 62 0 0 lt_lib.cap FCJ TY 196 60 2 2 0 0 0 Calibri C40 TY 196 64 2 2 0 0 0 Calibri 25p MC 180 94 1 0 120 FCJ TY 174 95 2 2 0 0 0 Calibri L7 TY 174 99 2 2 0 0 0 Calibri 1u MC 108 158 1 0 115 FCJ TY 98 153 2 2 0 0 0 Calibri R35 TY 100 160 2 2 0 0 0 Calibri 10K MC 144 108 0 0 115 FCJ TY 146 108 2 2 0 0 0 Calibri R30 TY 146 112 2 2 0 0 0 Calibri 330 SA 222 44 1 SA 202 16 1 SA 98 46 1 SA 222 16 1 SA 28 60 1 SA 48 82 1 LI 16 30 14 30 1 SA 28 30 1 SA 98 60 1 SA 52 38 1 SA 244 16 1 SA 148 30 1 LI 202 28 176 28 1 SA 124 38 1 SA 176 48 1 SA 68 108 1 SA 98 16 1 SA 108 108 1 SA 198 92 1 SA 64 46 1 SA 242 86 1 SA 234 46 1 SA 36 94 1 LI 212 44 212 42 1 SA 128 94 1 LI 234 28 234 16 1 SA 68 94 1 LI 36 46 28 46 1 SA 228 92 1 LI 28 30 24 30 1 SA 122 106 1 SA 258 60 1 SA 144 106 1 SA 98 74 1 SA 186 106 1 SA 258 74 1 LI 276 18 276 16 1 LI 148 30 148 26 1 LI 80 26 80 22 1 SA 148 16 1 LI 166 28 166 26 1 SA 176 16 1 LI 176 28 166 28 1 LI 202 16 176 16 1 SA 176 28 1 LI 222 16 212 16 1 LI 222 44 212 44 1 LI 244 16 234 16 1 SA 166 28 1 LI 276 16 268 16 1 LI 48 46 44 46 1 SA 98 30 1 LI 64 30 64 28 1 LI 138 18 138 16 1 LI 98 30 98 28 1 LI 166 18 166 16 1 LI 116 30 114 30 1 LI 166 40 166 38 1 LI 120 46 120 38 1 LI 176 40 166 40 1 LI 166 30 166 28 1 LI 194 40 192 40 1 LI 276 30 276 28 1 LI 124 42 124 38 1 LI 64 32 64 30 1 LI 194 58 194 48 1 LI 138 32 138 30 1 LI 28 60 28 58 1 LI 212 32 212 30 1 LI 44 60 42 60 1 LI 20 38 18 38 1 LI 64 60 64 58 1 LI 56 38 52 38 1 LI 70 46 64 46 1 LI 90 38 80 38 1 LI 80 46 78 46 1 LI 124 38 120 38 1 LI 98 46 84 46 1 LI 202 54 202 46 1 LI 236 60 234 60 1 LI 206 54 202 54 1 LI 138 46 138 44 1 LI 222 54 216 54 1 LI 162 46 160 46 1 LI 176 56 176 48 1 LI 244 46 244 38 1 SA 48 94 1 LI 28 48 28 46 1 SA 234 16 1 LI 98 48 98 46 1 SA 164 92 1 LI 176 48 176 40 1 SA 64 30 1 LI 194 48 194 40 1 LI 98 60 98 58 1 LI 234 48 234 46 1 LI 116 60 114 60 1 LI 124 54 124 52 1 LI 146 60 138 60 1 LI 258 74 138 74 1 SA 102 108 1 LI 18 78 18 38 1 LI 258 60 256 60 1 LI 276 78 276 74 1 LI 284 60 276 60 1 LI 244 80 242 80 1 LI 64 62 64 60 1 LI 268 80 268 16 1 LI 138 62 138 60 1 LI 48 82 36 82 1 LI 176 68 176 66 1 LI 198 82 198 80 1 LI 28 74 28 72 1 LI 48 84 48 82 1 LI 64 74 28 74 1 LI 242 86 240 86 1 LI 98 74 64 74 1 LI 144 92 128 92 1 LI 138 74 98 74 1 LI 164 92 162 92 1 SA 64 16 1 LI 192 92 192 82 1 SA 138 16 1 LI 198 92 198 90 1 SA 166 16 1 LI 206 92 198 92 1 SA 212 16 1 LI 216 92 214 92 1 LI 212 16 202 16 1 LI 232 92 228 92 1 LI 234 16 222 16 1 LI 244 92 242 92 1 LI 268 16 244 16 1 LI 256 92 252 92 1 LI 28 18 28 16 1 LI 36 94 20 94 1 SA 138 30 1 LI 48 94 36 94 1 SA 202 28 1 LI 68 94 68 78 1 SA 176 40 1 LI 102 94 88 94 1 SA 80 38 1 LI 128 94 128 92 1 SA 28 46 1 LI 134 94 128 94 1 SA 138 46 1 LI 180 94 180 92 1 SA 202 54 1 LI 68 96 68 94 1 SA 222 54 1 LI 108 96 108 94 1 SA 194 48 1 LI 134 96 134 94 1 SA 64 60 1 LI 216 96 216 92 1 SA 138 60 1 LI 20 98 20 94 1 SA 64 74 1 LI 48 98 48 94 1 SA 138 74 1 LI 198 102 198 92 1 SA 268 16 1 LI 118 106 118 94 1 SA 192 92 1 LI 122 106 118 106 1 SA 216 92 1 LI 134 106 130 106 1 SA 256 80 1 LI 168 106 144 106 1 LI 180 106 180 104 1 LI 180 106 168 106 1 SA 144 92 1 LI 190 106 186 106 1 LI 20 108 20 106 1 LI 20 108 16 108 1 SA 88 94 1 LI 58 108 56 108 1 SA 134 106 1 LI 68 108 66 108 1 SA 180 106 1 LI 102 108 98 108 1 SA 48 110 1 LI 116 108 108 108 1 LI 122 108 122 106 1 LI 134 108 134 106 1 LI 144 108 144 106 1 LI 180 108 180 106 1 LI 186 108 186 106 1 LI 216 108 216 104 1 LI 228 108 228 106 1 LI 36 110 36 106 1 LI 48 110 48 106 1 LI 48 110 36 110 1 LI 54 110 48 110 1 LI 68 110 68 108 1 LI 102 110 102 108 1 LI 108 110 108 108 1 LI 20 112 20 108 1 LI 36 112 36 110 1 LI 48 112 48 110 1 LI 122 118 122 116 1 LI 128 118 122 118 1 LI 134 118 134 116 1 LI 134 118 128 118 1 LI 128 120 128 118 1 LI 144 120 144 118 1 LI 144 120 128 120 1 LI 152 120 144 120 1 LI 164 120 164 104 1 LI 164 120 162 120 1 LI 180 120 180 118 1 LI 180 120 164 120 1 LI 186 120 186 118 1 LI 194 120 194 66 1 LI 194 120 186 120 1 LI 198 120 198 110 1 LI 198 120 194 120 1 LI 206 120 198 120 1 LI 240 120 240 98 1 LI 240 120 214 120 1 LI 242 120 240 120 1 LI 258 120 258 108 1 LI 258 120 252 120 1 LI 20 122 20 120 1 LI 36 122 36 120 1 LI 36 122 20 122 1 LI 48 122 48 120 1 LI 48 122 36 122 1 LI 54 122 54 110 1 LI 68 122 68 120 1 LI 68 122 54 122 1 LI 84 122 84 66 1 LI 84 122 68 122 1 LI 88 122 88 112 1 LI 88 122 84 122 1 LI 102 122 102 120 1 LI 102 122 88 122 1 LI 108 122 108 120 1 LI 130 122 130 106 1 LI 130 122 108 122 1 LI 258 122 258 120 1 LI 36 126 36 122 1 LI 48 126 48 122 1 LI 194 126 194 120 1 LI 194 126 110 126 1 LI 116 128 116 108 1 LI 168 128 168 106 1 LI 258 132 258 130 1 LI 36 136 36 134 1 LI 48 136 48 134 1 LI 48 136 36 136 1 LI 110 136 110 126 1 LI 110 136 48 136 1 LI 116 140 116 138 1 LI 140 140 116 140 1 LI 168 140 168 138 1 LI 168 140 148 140 1 LI 116 150 116 140 1 LI 168 150 168 140 1 LI 168 154 168 150 1 LI 82 158 70 158 1 LI 98 158 92 158 1 LI 116 158 116 150 1 LI 116 158 108 158 1 LI 124 158 116 158 1 LI 284 158 284 60 1 LI 284 158 134 158 1 SA 276 16 1 TY 188 113 2 2 0 1 1 Calibri SA 20 108 1 SA 36 110 1 SA 128 118 1 SA 144 120 1 SA 164 120 1 SA 194 120 1 SA 198 120 1 SA 240 120 1 SA 36 122 1 SA 68 122 1 SA 84 122 1 SA 88 122 1 SA 258 120 1 SA 48 122 1 SA 168 106 1 SA 48 136 1 SA 116 140 1 SA 168 140 1 SA 116 158 1 LI 64 16 28 16 1 LI 98 16 64 16 1 LI 138 16 98 16 1 LI 148 16 138 16 1 LI 166 16 148 16 1 LI 176 16 166 16 1 SA 276 74 1 LI 228 92 216 92 1 SA 276 60 1 LI 242 92 242 86 1 SA 116 150 1 LI 256 92 256 80 1 SA 168 150 1 LI 36 94 36 92 1 LI 64 18 64 16 1 LI 98 18 98 16 1 TY 26 38 2 2 0 1 1 Calibri LI 148 18 148 16 1 TY 30 22 2 2 0 1 1 Calibri LI 176 18 176 16 1 TY 30 51 2 2 0 1 1 Calibri LI 212 22 212 16 1 TY 30 66 2 2 0 1 1 Calibri LI 124 26 124 22 1 TY 280 22 2 2 0 1 1 Calibri LI 176 28 176 26 1 TY 280 82 2 2 0 1 1 Calibri LI 202 28 202 16 1 TY 38 62 2 2 0 1 1 Calibri LI 222 28 222 16 1 TY 20 32 2 2 0 1 1 Calibri LI 244 28 244 16 1 TY 66 22 2 2 0 1 1 Calibri LI 28 30 28 28 1 TY 66 52 2 2 0 1 1 Calibri LI 50 30 48 30 1 TY 54 46 2 2 0 1 1 Calibri LI 64 30 58 30 1 TY 66 66 2 2 0 1 1 Calibri LI 106 30 98 30 1 TY 58 62 2 2 0 1 1 Calibri LI 138 30 138 28 1 TY 54 32 2 2 0 1 1 Calibri LI 148 30 138 30 1 TY 100 22 2 2 0 1 1 Calibri LI 176 30 176 28 1 TY 100 52 2 2 0 1 1 Calibri LI 28 32 28 30 1 TY 82 31 2 2 0 1 1 Calibri LI 98 32 98 30 1 TY 100 66 2 2 0 1 1 Calibri LI 148 32 148 30 1 TY 110 62 2 2 0 1 1 Calibri LI 202 34 202 28 1 TY 110 32 2 2 0 1 1 Calibri LI 52 38 48 38 1 TY 140 22 2 2 0 1 1 Calibri LI 80 38 80 36 1 TY 140 52 2 2 0 1 1 Calibri LI 124 38 124 36 1 TY 126 31 2 2 0 1 1 Calibri LI 130 38 124 38 1 TY 140 66 2 2 0 1 1 Calibri LI 176 40 176 38 1 TY 150 62 2 2 0 1 1 Calibri LI 182 40 176 40 1 TY 150 37 2 2 0 1 1 Calibri LI 52 42 52 38 1 TY 40 48 2 2 0 1 1 Calibri LI 148 42 148 40 1 TY 74 48 2 2 0 1 1 Calibri LI 222 44 222 36 1 TY 110 48 2 2 0 1 1 Calibri LI 28 46 28 44 1 TY 156 48 2 2 0 1 1 Calibri LI 48 46 48 38 1 TY 62 38 2 2 0 1 1 Calibri LI 64 46 64 44 1 TY 96 38 2 2 0 1 1 Calibri LI 80 46 80 38 1 TY 136 38 2 2 0 1 1 Calibri LI 98 46 98 44 1 TY 126 46 2 2 0 1 1 Calibri LI 106 46 98 46 1 TY 150 22 2 2 0 1 1 Calibri LI 120 46 114 46 1 TY 200 40 2 2 0 1 1 Calibri LI 152 46 138 46 1 TY 178 23 2 2 0 1 1 Calibri LI 234 46 234 38 1 TY 168 23 2 2 0 1 1 Calibri LI 244 46 234 46 1 TY 168 35 2 2 0 1 1 Calibri LI 64 48 64 46 1 TY 187 40 2 2 0 1 1 Calibri LI 138 48 138 46 1 TY 211 54 2 2 0 1 1 Calibri LI 178 48 176 48 1 TY 182 50 2 2 0 1 1 Calibri LI 194 48 186 48 1 TY 178 60 2 2 0 1 1 Calibri LI 52 54 52 52 1 TY 178 33 2 2 0 1 1 Calibri LI 162 54 162 46 1 TY 234 50 2 2 0 1 1 Calibri LI 202 54 162 54 1 TY 236 32 2 2 0 1 1 Calibri LI 222 54 222 44 1 TY 246 32 2 2 0 1 1 Calibri LI 226 54 222 54 1 TY 240 62 2 2 0 1 1 Calibri LI 84 58 84 46 1 TY 260 66 2 2 0 1 1 Calibri LI 222 58 222 54 1 TY 251 62 2 2 0 1 1 Calibri LI 34 60 28 60 1 TY 224 33 2 2 0 1 1 Calibri LI 54 60 52 60 1 TY 214 27 2 2 0 1 1 Calibri LI 64 60 62 60 1 TY 214 36 2 2 0 1 1 Calibri LI 106 60 98 60 1 TY 238 92 2 2 0 1 1 Calibri LI 138 60 138 58 1 TY 249 82 2 2 0 1 1 Calibri LI 156 60 154 60 1 TY 248 94 2 2 0 1 1 Calibri LI 246 60 244 60 1 TY 230 100 2 2 0 1 1 Calibri LI 276 60 258 60 1 TY 218 101 2 2 0 1 1 Calibri LI 28 62 28 60 1 TY 247 122 2 2 0 1 1 Calibri LI 98 62 98 60 1 TY 260 103 2 2 0 1 1 Calibri LI 258 62 258 60 1 TY 260 127 2 2 0 1 1 Calibri LI 222 70 222 68 1 TY 210 122 2 2 0 1 1 Calibri LI 64 74 64 72 1 TY 210 94 2 2 0 1 1 Calibri LI 98 74 98 72 1 TY 200 107 2 2 0 1 1 Calibri LI 138 74 138 72 1 TY 200 87 2 2 0 1 1 Calibri LI 258 74 258 72 1 TY 188 99 2 2 0 1 1 Calibri LI 276 74 258 74 1 TY 68 116 2 2 0 1 1 Calibri LI 68 78 18 78 1 TY 177 113 2 2 0 1 1 Calibri LI 216 80 216 78 1 TY 177 99 2 2 0 1 1 Calibri LI 256 80 254 80 1 TY 166 101 2 2 0 1 1 Calibri LI 268 80 256 80 1 TY 157 94 2 2 0 1 1 Calibri LI 192 82 48 82 1 TY 157 122 2 2 0 1 1 Calibri LI 36 84 36 82 1 TY 146 98 2 2 0 1 1 Calibri LI 242 86 242 80 1 TY 146 112 2 2 0 1 1 Calibri LI 276 90 276 88 1 TY 136 102 2 2 0 1 1 Calibri LI 152 92 144 92 1 TY 136 114 2 2 0 1 1 Calibri LI 180 92 164 92 1 TY 124 114 2 2 0 1 1 Calibri LI 192 92 186 92 1 TY 124 102 2 2 0 1 1 Calibri LI 198 92 192 92 1 TY 110 101 2 2 0 1 1 Calibri LI 216 92 216 90 1 TY 110 115 2 2 0 1 1 Calibri TY 220 84 2 2 0 1 1 Calibri 5Meg TY 99 101 2 2 0 1 1 Calibri LI 186 106 186 104 1 TY 99 115 2 2 0 1 1 Calibri TY 224 55 2 2 0 1 1 Calibri I2 TY 118 132 2 2 0 1 1 Calibri LI 56 108 56 94 1 TY 170 132 2 2 0 1 1 Calibri LI 48 94 48 92 1 TY 144 142 2 2 0 1 1 Calibri LI 56 94 48 94 1 TY 90 109 2 2 0 1 1 Calibri LI 88 94 68 94 1 TY 70 102 2 2 0 1 1 Calibri LI 118 94 108 94 1 LI 122 106 122 104 1 LI 128 94 122 94 1 TY 62 110 2 2 0 1 1 Calibri LI 144 94 144 92 1 TY 50 103 2 2 0 1 1 Calibri LI 186 94 186 92 1 TY 38 103 2 2 0 1 1 Calibri LI 102 96 102 94 1 TY 50 117 2 2 0 1 1 Calibri LI 122 96 122 94 1 TY 38 117 2 2 0 1 1 Calibri LI 164 96 164 92 1 TY 50 131 2 2 0 1 1 Calibri LI 228 96 228 92 1 TY 38 131 2 2 0 1 1 Calibri LI 36 98 36 94 1 TY 38 89 2 2 0 1 1 Calibri LI 258 98 258 74 1 TY 50 89 2 2 0 1 1 Calibri LI 88 104 88 94 1 TY 22 103 2 2 0 1 1 Calibri TY 220 81 2 2 0 1 1 Calibri 0 100u TY 22 117 2 2 0 1 1 Calibri LI 134 106 134 104 1 TY 196 64 2 2 0 1 1 Calibri LI 144 106 144 104 1 TY 129 160 2 2 0 1 1 Calibri LI 102 108 102 106 1 TY 220 78 2 2 0 1 1 Calibri LI 108 108 108 106 1 TY 226 67 2 2 0 1 1 Calibri 10u 0) TY 103 160 2 2 0 1 1 Calibri TY 226 60 2 2 0 1 1 Calibri LI 68 108 68 106 1 TY 87 162 2 2 0 1 1 Calibri TY 86 63 2 2 0 1 1 Calibri TY 278 12 4 2 0 1 2 Calibri +15V TY 278 70 4 2 0 1 2 Calibri -V TY 118 146 4 2 0 1 2 Calibri -IN TY 270 54 4 2 0 1 2 Calibri OUT TY 170 146 4 2 0 1 2 Calibri +IN RV 270 146 10 10 2 FCJ 2 0 TY 178 131 2 2 0 1 15 Calibri model 1N2326 D(Is=7.8u Rs=3 Cjo=4p Eg=.67) TY 178 135 2 2 0 1 15 Calibri model 1N484 D(Rs=3 Cjo=4p type=silicon) TY 178 139 2 2 0 1 15 Calibri model 2N344 PNP(Is=1e-10 bf=11 Vaf=15 Cje=5p Cjc=2.5p Tf=3n TY 178 143 2 2 0 1 15 Calibri + Eg=.67 Rb=100 Re=10) TY 202 152 2 2 0 1 15 Calibri tran 1.2m TY 175 89 2 2 0 1 15 Calibri K1 L4 L5 TY 174 93 2 2 0 1 15 Calibri + L6 L7 1 TY 97 91 2 2 0 1 15 Calibri K2 L8 L9 TY 95 95 2 2 0 1 15 Calibri + L10 L11 1 TY 178 127 2 2 0 1 15 Calibri model V47 D(Is=3p Cjo=105p) TY 12 122 2 2 0 1 15 Calibri param y=.49 TY 72 12 2 2 0 1 15 Calibri George A. Philbrick Researches, Inc. P2 All Solid State Differential Operational Amplifier TY 14 148 1 1 0 1 15 Calibri This example schematic is supplied for TY 14 150 1 1 0 1 15 Calibri informational/educational purposes only. TY 63 132 2 2 0 1 15 Calibri www.philbrickarchive.org TY 13 126 2 2 0 1 15 Calibri Gain Adj. TY 62 126 2 2 0 1 15 Calibri Offset Adj. TY 16 137 2 2 0 1 15 Calibri model 2N274 PNP(Is=1e-10 bf=20 Vaf=10 Cje=25p Cjc=25p Eg=.67) TY 16 141 2 2 0 1 15 Calibri model 2N597 PNP(Is=1e-10 bf=50 Vaf=10 Cje=50p Cjc=10p Eg=.67) TY 61 122 2 2 0 1 15 Calibri param x=.735